World Wide Completely Free Returns and Shipping

megger-torkel-860

MEGGER

TORKEL 860

BATTERY DISHARGE KIT- 480 V DC (TORKEL 860) BATTERY DISCHARGE KIT MANUFACTURE : MEASUREMENT SECTION: CURRENT MEASUREMENT: DISPLAY RANGE: 0.0 – 2999 A ACCURACY: ± (0.5% OF READING +0.2 A) RESOLUTION: 0.1 A INTERNAL CURRENT MEASUREMENT: RANGE: 0 – 270 A INPUT FOR CLAMP-ON AMMETER: RANGE: 0 – 1 V MV/A-RATIO: SOFTWARE SETTABLE, 0.3 TO 19.9 MV/A INPUT IMPEDANCE : >1 MΩ VOLTAGE MEASUREMENT DISPLAY RANGE: 0.0 – 60 V ACCURACY: ± (0.5% OF READING +0.1 V) RESOLUTION: 0.1 V DISPLAY RANGE: 0.0 – 500 V ACCURACY: ±(0.5% OF READING +1 V) RESOLUTION: 0.1 V TIME MEASUREMENT ACCURACY: ±0.1% OF READING ±1 DIGIT LOAD SECTION MAX. BATTERY VOLTAGE: 480 V DC (TORKEL 860) MAX. CURRENT 110 A. MAX. POWER: 15 KW. LOAD PATTERNS: CONSTANT CURRENT, CONSTANT POWER, CONSTANT RESISTANCE, CURRENT OR POWER PROFILE CURRENT SETTING: 0-110.0 A (2999.9 A) 1. POWER SETTING: 0-15.00 KW (299.99 KW) 1 RESISTANCE SETTING: 0.1-2999.8Ω. BATTERY VOLTAGE RANGE: 5 RANGES, SELECTED AUTOMATICALLY AT TORKEL 860START OF TEST STABILIZATION ± (0.5% OF READING +0.5 A) (FOR INTERNAL) MEASUREMENT SECTION CURRENT MEASUREMENT DISPLAY RANGE 0.0 – 2999 ACCURACY ± (0.5% OF READING +0.2 A) RESOLUTION 0.1 A

Get a quote now for MEGGER TORKEL 860. We will send you the price offer within 24 hours. If you send us the other products you are looking for but cannot find on our website, we can supply them for you.

Brand:
Part No:
  • TORKEL 860

Description:
  • BATTERY DISHARGE KIT- 480 V DC (TORKEL 860) BATTERY DISCHARGE KIT MANUFACTURE : MEASUREMENT SECTION: CURRENT MEASUREMENT: DISPLAY RANGE: 0.0 – 2999 A ACCURACY: ± (0.5% OF READING +0.2 A) RESOLUTION: 0.1 A INTERNAL CURRENT MEASUREMENT: RANGE: 0 – 270 A INPUT FOR CLAMP-ON AMMETER: RANGE: 0 – 1 V MV/A-RATIO: SOFTWARE SETTABLE, 0.3 TO 19.9 MV/A INPUT IMPEDANCE : >1 MΩ VOLTAGE MEASUREMENT DISPLAY RANGE: 0.0 – 60 V ACCURACY: ± (0.5% OF READING +0.1 V) RESOLUTION: 0.1 V DISPLAY RANGE: 0.0 – 500 V ACCURACY: ±(0.5% OF READING +1 V) RESOLUTION: 0.1 V TIME MEASUREMENT ACCURACY: ±0.1% OF READING ±1 DIGIT LOAD SECTION MAX. BATTERY VOLTAGE: 480 V DC (TORKEL 860) MAX. CURRENT 110 A. MAX. POWER: 15 KW. LOAD PATTERNS: CONSTANT CURRENT, CONSTANT POWER, CONSTANT RESISTANCE, CURRENT OR POWER PROFILE CURRENT SETTING: 0-110.0 A (2999.9 A) 1. POWER SETTING: 0-15.00 KW (299.99 KW) 1 RESISTANCE SETTING: 0.1-2999.8Ω. BATTERY VOLTAGE RANGE: 5 RANGES, SELECTED AUTOMATICALLY AT TORKEL 860START OF TEST STABILIZATION ± (0.5% OF READING +0.5 A) (FOR INTERNAL) MEASUREMENT SECTION CURRENT MEASUREMENT DISPLAY RANGE 0.0 – 2999 ACCURACY ± (0.5% OF READING +0.2 A) RESOLUTION 0.1 A