World Wide Completely Free Returns and Shipping

vem-tefcic411

VEM

TEFC/IC411

induction motor Dimensions in all directions are not a problem, The important thing to consider is that the type of cooling complies with the IC411 version, since there is humidity in the place where it is installed. 3-PHASE 2000 HP 1200 rpm; 4160 volts FRAME 560 Enclosure: TEFC/IC411 Totally Enclosed, Fan-Cooled (TEFC) # Horizontal mounting B3; # Service factor: 1.15; # Class F insulation, Class B temperature rise @ 1.0 service factor; Class F temperature rise @ 1.15 service factor; # Service duty: S1 continuous; # Start method: DOL; VFD capability: CT2:1; # Ambient temperature: -20/45C; # Application: outdoors; # Protection of motor/terminal box: IP55/IP55; # 2 off three-wire type simplex PT100 per phase for stator winding; # 1 off three-wir e type duplex PT100 for each bearing; Note 1: Regarding dimensional distances from legs bores: is not an issue, they will make mechanical adaptations to their facility for new motor mounting, this is an outdoor installation so any other dimension of the motor are no issue as long as shaft is machined as specified If further detail are needed please let us know to investigate, let us know if this is something you guys would be able to quote Regards

Get a quote now for VEM TEFC/IC411. We will send you the price offer within 24 hours. If you send us the other products you are looking for but cannot find on our website, we can supply them for you.

Brand:
Part No:
  • TEFC/IC411

Description:
  • induction motor Dimensions in all directions are not a problem, The important thing to consider is that the type of cooling complies with the IC411 version, since there is humidity in the place where it is installed. 3-PHASE 2000 HP 1200 rpm; 4160 volts FRAME 560 Enclosure: TEFC/IC411 Totally Enclosed, Fan-Cooled (TEFC) # Horizontal mounting B3; # Service factor: 1.15; # Class F insulation, Class B temperature rise @ 1.0 service factor; Class F temperature rise @ 1.15 service factor; # Service duty: S1 continuous; # Start method: DOL; VFD capability: CT2:1; # Ambient temperature: -20/45C; # Application: outdoors; # Protection of motor/terminal box: IP55/IP55; # 2 off three-wire type simplex PT100 per phase for stator winding; # 1 off three-wir e type duplex PT100 for each bearing; Note 1: Regarding dimensional distances from legs bores: is not an issue, they will make mechanical adaptations to their facility for new motor mounting, this is an outdoor installation so any other dimension of the motor are no issue as long as shaft is machined as specified If further detail are needed please let us know to investigate, let us know if this is something you guys would be able to quote Regards